Light Duty Exterior Fiberglass Doors

Fiberglass Standard Duty

Finger Jointed

414" Finger-jointed 4-ply hardwood hinge and strike stile

Stiles and Rails

Stiles and rails are dovetailed and glued at each corner

Finger Jointed

258" Finger-jointed 4-ply hardwood hinge stile

Ball Bearing Hinge

Four Ball Bearing Hinges

Fire Rating

Listed Fire Door 20 Minute Rating (with specialty core)

 

 

FIBERGLASS

  • Realistic Woodgrain Appearance from nickel vapor deposition technology
  • Energy Efficient Polyurethane Foam Core
  • Architecturally Correct Woodgrain Texture
  • Strong Solid Wood Perimeter Frame
  • Aluminum Threshold is Standard
  • Energy Efficient Q-Lon Weatherstripping
  • Factory Pre-Finishing is Available
  • DuraFuse Finishing System Featuring P3 Fusion
 

FIBERGLASS DOOR STANDARD SPECIFICATIONS

Fiberglass Slab with High Definition Woodgrain Face

FRAME

4 916" Full Wood Frame

DOOR TOP & BOTTOM REINFORCEMENTS

Poplar Top Rail & Composite Bottom Rail

PERIMETER

3-Ply, Finger-Jointed Solid Wood

DOOR EDGES

Door edges of Cherry, Oak or Mahogany

DOOR CORE

Polyurethane Core: Foamed in place polyurethane with a U-factor as low as .17

HINGES

Three Ball Bearing Hinges

THRESHOLD

Bronze Sahara Threshold

HARDWARE

None

EDGE PREP

1" x 214"

WARRANTY

Non-Residential Warranty

PAINT

1 color both sides (inside frame painted to match)

WINDOW TRIM

Standard (where applicable)

STRIKE LOCATION

343/4"

LOCKSET& DEADBOLT PREP

512" Center to Center

FRENCH DOORS

T Astragal (96" French Doors are not available)

FIBERGLASS DOOR TESTING

Doors have been tested and certified to NFRC (National Fenestration Rating Council) 100 and NFRC 200 guidelines enabling the ENERGY STAR Thermal Performance Qualification.

IMPACT TEST

Test Performed: ASTM F476 Forced Entry Test
Result: Maximum Security Level of 40

WIND LOAD RATING TEST

Test Performed: ASTM E330 Structural Wind Load Resistance
Result: DP (Design Pressure) =±85 psf for
3' 0" x 6' 8" Glazed Single Door

ACOUSTICAL PERFORMANCE TEST

Test Performed: ASTM E90
Result: STC=26 Standard Opaque Door

FIRE RESISTANCE TEST

Test Performed: NFPA 252, CAN4 S 104, UL10C
Result: 20 Minute Category A

 

Additional Available Options:

  • Wood Closer Reinforcement
  • No Face Prep
  • Mortise Face Prep
  • No Edge Preps
  • 218" Cylindrical Lockset Facepreps
  • 158" or 218" Cylindrical Lockset Facepreps
  • Strike Plate Preps: 214" or 478"
  • 20 Minute Fire Rating
  • Edge Preps 118" x 214", or 114 x 8" or Trilennium
  • 18-Gauge Hollow Metal Masonry Frame
  • 18-Gauge Hollow Metal Drywall Frame
  • 18-Gauge Redi-Flex Adjustable Steel Frame
  • Threshold Options: No Threshold,
    Saddle Threshold, ADA Compliant Threshold
  • All Glass Styles